Factory Outlets For 110vac To 220vac Transformer - Three phase AC Type input reactor – Xinping
Factory Outlets For 110vac To 220vac Transformer - Three phase AC Type input reactor – Xinping Detail:
Characteristic
Effectively restrain harmonic current, improve the power factor of the whole machine, effectively restrain the current impact caused by the sudden change of grid voltage and over-voltage, improve the interference of the power supply to other equipment, and improve the unbalanced voltage between power supply phases that is greater than the rated voltage
Technical Data | |
Rated Voltage: | 380V/440V |
Operation Frequency: | 50/60HZ |
Rated Current: | 3A-1600A |
Hi-pot Test: | 3.5kV, 60sec |
Insulation Class: | F or above |
Reactor Impedance: | 2% |
Ambient temperature: | -25^ to 401: |
Protection Category: | I POO |
Design corresponding to Standards: | GB19212.1-2008 / GB19212.21-2007 /GB1094.6-2011 |
Application Schematic
Outline dimension drawing
Type Selection Table |
|||||||
|
|
(mH) |
(A) |
m(m) Dimensions 1 |
|||
Model |
Power (KW) |
Inductance |
Rated Current |
L |
W |
H |
Installation dimensions E*F |
5A |
1.5 |
2.80 |
5 |
160 |
120 |
140 |
80*60 |
7A |
2.2 |
2.00 |
7 |
160 |
120 |
140 |
80*60 |
10A |
3.7 |
1.40 |
10 |
160 |
120 |
140 |
80*60 |
ISA |
5.5 |
0.93 |
15 |
160 |
120 |
140 |
80*60 |
20A |
7.5 |
0.70 |
20 |
160 |
120 |
140 |
80*60 |
30A |
11 |
0.47 |
30 |
160 |
120 |
140 |
80*60 |
40A |
15 |
0.35 |
40 |
160 |
120 |
140 |
80*60 |
50A |
18.5 |
0.28 |
50 |
160 |
130 |
140 |
80*75 |
60A |
22 |
0.24 |
60 |
160 |
140 |
140 |
80*85 |
80A |
30 |
0.17 |
80 |
190 |
150 |
160 |
80*85 |
90A |
37 |
0.16 |
90 |
190 |
150 |
160 |
80*85 |
120A |
45 |
0.12 |
120 |
190 |
150 |
160 |
80*95 |
150A |
55 |
0.09 |
150 |
225 |
160 |
190 |
120*85 |
200A |
75 |
0.07 |
200 |
225 |
160 |
220 |
120*85 |
220A |
90 |
0.064 |
220 |
225 |
170 |
220 |
120*95 |
250A |
110 |
0.056 |
250 |
225 |
180 |
220 |
120*95 |
290A |
132 |
0.047 |
290 |
260 |
160 |
250 |
135*85 |
330A |
160 |
0.042 |
330 |
260 |
170 |
250 |
135*95 |
390A |
185 |
0.036 |
390 |
260 |
170 |
250 |
135*95 |
440A |
200 |
0.032 |
440 |
260 |
170 |
250 |
135*95 |
490A |
220 |
0.028 |
490 |
260 |
180 |
250 |
135*95 |
540A |
250 |
0.025 |
540 |
290 |
200 |
310 |
135*95 |
600A |
280 |
0.023 |
600 |
290 |
210 |
310 |
135*95 |
700A |
315 |
0.021 |
700 |
290 |
210 |
310 |
135*105 |
800A |
350 |
0.018 |
800 |
290 |
220 |
310 |
135*125 |
1000A |
400 |
0.014 |
1000 |
290 |
230 |
310 |
Note: The above specifications are the company’s standard products, and the product performance, size and appearance can be customized according to the customer’s products.
Product Display
Product detail pictures:
Related Product Guide:
We thinks what buyers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better high-quality, reduced processing costs, charges are more reasonable, won the new and outdated consumers the support and affirmation for Factory Outlets For 110vac To 220vac Transformer - Three phase AC Type input reactor – Xinping , The product will supply to all over the world, such as: belarus, Rio de Janeiro, Croatia, Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards reasonable prices, efficient production time and good after-sales service as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.