Characteristic
Effectively restrain harmonic current, improve the power factor of the whole machine, effectively restrain the current impact caused by the sudden change of grid voltage and over-voltage, improve the interference of the power supply to other equipment, and improve the unbalanced voltage between power supply phases that is greater than the rated voltage
Technical Data | |
Rated Voltage: | 380V/440V |
Operation Frequency: | 50/60HZ |
Rated Current: | 3A-1600A |
Hi-pot Test: | 3.5kV, 60sec |
Insulation Class: | F or above |
Reactor Impedance: | 2% |
Ambient temperature: | -25^ to 401: |
Protection Category: | I POO |
Design corresponding to Standards: | GB19212.1-2008 / GB19212.21-2007 /GB1094.6-2011 |
Application Schematic
Outline dimension drawing
Type Selection Table |
|||||||
|
|
(mH) |
(A) |
m(m) Dimensions 1 |
|||
Model |
Power (KW) |
Inductance |
Rated Current |
L |
W |
H |
Installation dimensions E*F |
5A |
1.5 |
2.80 |
5 |
160 |
120 |
140 |
80*60 |
7A |
2.2 |
2.00 |
7 |
160 |
120 |
140 |
80*60 |
10A |
3.7 |
1.40 |
10 |
160 |
120 |
140 |
80*60 |
ISA |
5.5 |
0.93 |
15 |
160 |
120 |
140 |
80*60 |
20A |
7.5 |
0.70 |
20 |
160 |
120 |
140 |
80*60 |
30A |
11 |
0.47 |
30 |
160 |
120 |
140 |
80*60 |
40A |
15 |
0.35 |
40 |
160 |
120 |
140 |
80*60 |
50A |
18.5 |
0.28 |
50 |
160 |
130 |
140 |
80*75 |
60A |
22 |
0.24 |
60 |
160 |
140 |
140 |
80*85 |
80A |
30 |
0.17 |
80 |
190 |
150 |
160 |
80*85 |
90A |
37 |
0.16 |
90 |
190 |
150 |
160 |
80*85 |
120A |
45 |
0.12 |
120 |
190 |
150 |
160 |
80*95 |
150A |
55 |
0.09 |
150 |
225 |
160 |
190 |
120*85 |
200A |
75 |
0.07 |
200 |
225 |
160 |
220 |
120*85 |
220A |
90 |
0.064 |
220 |
225 |
170 |
220 |
120*95 |
250A |
110 |
0.056 |
250 |
225 |
180 |
220 |
120*95 |
290A |
132 |
0.047 |
290 |
260 |
160 |
250 |
135*85 |
330A |
160 |
0.042 |
330 |
260 |
170 |
250 |
135*95 |
390A |
185 |
0.036 |
390 |
260 |
170 |
250 |
135*95 |
440A |
200 |
0.032 |
440 |
260 |
170 |
250 |
135*95 |
490A |
220 |
0.028 |
490 |
260 |
180 |
250 |
135*95 |
540A |
250 |
0.025 |
540 |
290 |
200 |
310 |
135*95 |
600A |
280 |
0.023 |
600 |
290 |
210 |
310 |
135*95 |
700A |
315 |
0.021 |
700 |
290 |
210 |
310 |
135*105 |
800A |
350 |
0.018 |
800 |
290 |
220 |
310 |
135*125 |
1000A |
400 |
0.014 |
1000 |
290 |
230 |
310 |
Note: The above specifications are the company’s standard products, and the product performance, size and appearance can be customized according to the customer’s products.
Product Display
Product detail pictures:
Related Product Guide:
We take customer-friendly, quality-oriented, integrative, innovative as objectives. Truth and honesty is our administration ideal for Short Lead Time For 120 Volt Ac To 6 Volt Dc Transformer - Three phase AC Type input reactor – Xinping , The product will supply to all over the world, such as: Greece, Panama, Brunei, Aiming to grow to be by far the most professional supplier within this sector in Uganda, we keep researching on the creating procedure and raising the high quality of our principal goods. Till now, the merchandise list has been updated on a regular basis and attracted customers from around the globe. Detailed data can be obtained in our web page and you'll be served with good quality consultant service by our after-sale team. They're going to allow you to get complete acknowledge about our items and make a satisfied negotiation. Small business check out to our factory in Uganda can also be welcome at any time. Hope to obtain your inquiries to get a happy co-operation.